Buying an AI medical device software company: Health Canada rules

Two women review a book and a laptop together at a desk with sticky notes on a nearby post.
Photo by Vitaly Gariev on Unsplash

Software is a medical device when its intended or represented use is a medical purpose in the Act’s definition. Subject to section 37, no person may import or sell a Class II, III or IV device unless its manufacturer holds a licence for it or, after a section 34 change, an amended licence.

Software qualifies as a medical device when its intended or represented use is for one or more of the medical purposes in the definition of a device in the Act. This guide walks through the federal rules a buyer meets when the target sells AI software that may be a medical device: the software as a medical device definition, classification, the machine-learning guidance, change plans, licence amendments, good machine learning practice, licence checks and quality system certificates. It covers federal rules only, and it does not say whether any particular product is a medical device or what a change of owner does to a licence, so ask Health Canada or a regulatory lawyer about both.

When AI software is a medical device

Health Canada’s guidance on software as a medical device (SaMD) says its purpose is to clarify how SaMD fits into Health Canada’s regulatory framework for medical devices, based on its current interpretation of the definitions of “device” and “medical device” in the Act and Regulations. The guidance defines SaMD as software intended to be used for one or more medical purposes that perform these purposes without being part of a hardware medical device. “Without being part of” means software that is not necessary for a hardware medical device to achieve its intended medical purpose. Software does not meet the SaMD definition if its intended purpose is to drive a hardware medical device.

Intended use is a key consideration in deciding whether software is SaMD. The guidance says the intended use of SaMD is normally reflected in sources such as the manufacturer’s labelling, including instructions for use manuals, websites, promotional material and other information the manufacturer provides. Ask the target for its labelling, instructions for use, website and promotional material, so that you can read what they say the software is for.

Among the ways Health Canada generally interprets medical purposes in section 2.1 of the guidance is software intended to acquire, process or analyze a medical image, or a signal from an in vitro diagnostic device or a pattern or signal from a signal acquisition system. Another is software intended to support or give recommendations to health care professionals, patients or non-healthcare professional caregivers about prevention, diagnosis, treatment or mitigation of a disease or condition. Some clinical decision support or patient decision support (CDS/PDS) products are regulated as medical devices under the Regulations if they are intended to be used for medical purposes as the guidance defines them.

Section 2.2 records Health Canada’s longstanding position that some types of software are not medical devices, including software intended for administrative support of a healthcare facility and general wellness apps intended for maintaining or encouraging a healthy lifestyle. Section 2.2 also says that various types of clinical decision support or patient decision support software may not meet the device definition, and so would not be subject to the Regulations, when the software meets all four criteria the guidance lists. The guidance adds that those exclusion criteria are only a foundation for an analysis and should not be interpreted as a rigid set of exclusion factors. Among those criteria is that the software is not intended to replace the clinical judgement of a health care professional to make a clinical diagnosis or treatment decision regarding an individual patient. Ask the target how it decided that its software falls inside or outside the definition, and ask to see the written analysis.

Classification decides the licence

The guidance says the information and documentation required to support a medical device licence application is proportional to the risk of the device, which is determined by applying the Classification Rules for Medical Devices in Schedule 1 of the Regulations. Under section 6 of the Regulations, medical devices are classified into one of four classes, where Class I is the lowest risk and Class IV the highest. The classification of SaMD depends on the manufacturer’s labelled intended use and the applicable classification rules in Schedule 1.

Every SaMD has its own independent classification, even when it is interfaced with other SaMD or hardware medical devices, or used as a module in a larger system. SaMD that is intended to be used across multiple healthcare situations or conditions is classified at the highest classification under section 7 of the Regulations. Rule 10(2) classifies devices intended to monitor, assess or diagnose a disease, a disorder, an abnormal physical state or a pregnancy, where erroneous readings could result in immediate danger, as Class III. As an example, the guidance says a SaMD whose intended use statement says it would be used in a serious healthcare situation, and will be used to treat, diagnose or drive clinical management, would be a Class II medical device under Rule 10(1).

Manufacturers must determine the risk class of the SaMD based on its intended use and the applicable rules in Schedule 1, and the Medical Devices Bureau confirms the risk class upon review of the licence application. If the manufacturer and Health Canada disagree about the classification, the final decision rests with Health Canada, but the manufacturer may request a reconsideration. Ask which class the target has declared, on what reasoning, and whether Health Canada has ever confirmed or changed it.

Under section 26 of the Medical Devices Regulations, subject to section 37, no person may import or sell a Class II, III or IV medical device unless the manufacturer holds a licence for that device or, if the device has been subjected to a change described in section 34, an amended licence.

What Health Canada expects in a machine-learning device application

Health Canada’s guidance on machine learning-enabled medical devices (MLMD) says that medical devices that use machine learning, in part or in whole, to achieve their intended medical purpose are known as MLMD. The guidance is for manufacturers submitting a new or amendment application for a Class II, III or IV MLMD under the Regulations. It says the risk classification of an MLMD can range from Class I to Class IV.

For all Class II, III and IV applications for an MLMD, manufacturers should clearly state in the cover letter that the device uses machine learning, and should include a justification for the proposed classification. The MLMD guidance says Class II, III and IV applications must include the information listed in section 32 of the Regulations. Manufacturers must ensure that objective evidence is available to support the intended use of the MLMD, the safety and effectiveness of the device and the associated claims. Any data used to develop the MLMD or demonstrate its safety and effectiveness should reflect the population for whom the device is intended.

In a licence application for a Class III or IV MLMD, manufacturers should provide the appropriate clinical evidence, including clinical validation studies, to support the safe and effective clinical use of the device, and this information should be available upon request for a Class II MLMD. Additional information may be requested at any time during Health Canada’s review of an application, new or amendment, or after a device has been licensed. Ask the seller for the cover letter, the classification justification and any requests for additional information Health Canada has sent.

Predetermined change control plans: retraining without a significant-change amendment

The MLMD guidance says a predetermined change control plan (PCCP) is the documentation intended to describe changes that will be made to the MLMD as well as the device bounds or limits (for example, the performance envelope) and how the changes will be implemented and assessed. A PCCP includes a change description, a change protocol and an impact assessment. The changes described in a PCCP include those that would otherwise require a licence amendment application for a significant change before implementation.

For devices authorized with a PCCP, later changes made according to the authorized PCCP do not require an amendment application for a significant change. PCCP-driven changes are still subject to other licence amendment requirements, such as a change in the identifier of the device, and to relevant post-market regulatory oversight.

A PCCP may be submitted with an application for a new licence or a licence amendment, and manufacturers may consider the pre-submission process to discuss a proposed PCCP before submitting an application. If included, a PCCP is considered part of the device design, and manufacturers of an MLMD with a PCCP should clearly state in their cover letter that the device includes a PCCP. All modifications listed in a PCCP must ensure that the device continues to operate within its intended use, and the changes listed should not include changes to the medical conditions, purposes or uses of an MLMD.

The five joint principles

The FDA, Health Canada and the MHRA jointly identified five guiding principles for predetermined change control plans. The principles draw upon the overarching GMLP guiding principles, in particular principle 10, which states that deployed models are monitored for performance and re-training risks are managed. A PCCP describes specific changes that a manufacturer intends to implement. The document says the value and reliability of a PCCP is strengthened when its intent, design and implementation are driven by a risk-based approach that adheres to the principles of risk management. The principles include that methods to generate evidence are specified that demonstrate the benefits and risks of the device before and after the changes specified in the PCCP are implemented. The best practice, the document says, is to provide clear and appropriate information and detailed plans for ongoing transparency to users and other stakeholders.

Ask whether the target’s model is retrained and, if so, whether the retraining is described in an authorized PCCP.

Significant changes and licence amendments

Section 1 of the Medical Devices Regulations defines a significant change as a change that could reasonably be expected to affect the safety or effectiveness of a medical device. The definition includes a change to the design of the device, including its software. It also includes a change to the manufacturing process, facility or equipment, and to the intended use of the device, including any new or extended use.

Under section 34, if the manufacturer proposes to make one of the listed changes, it must submit to the Minister, in the format the Minister establishes, an application for a licence amendment including the information and documents in section 32 that are relevant to the change. The table below sets out some of the listed changes.

Some of the changes section 34 lists

Section 34 itemWhat the Regulations sayWhat to ask
Significant change (para. (a))In the case of a Class III or IV medical device, a significant change.Ask for each release since licensing that touched the design or software.
Change of class (para. (b))A change that would affect the class of the device.Ask whether any change has moved the declared class.
Names (paras. (c), (d))A change in the name of the manufacturer, and a change in the name of the device.Ask a regulatory lawyer whether a renaming planned after closing is covered.
Identifier (para. (e))A change in the identifier of the device, including the identifier of any medical device that is part of a system, test kit, medical device group, medical device family or medical device group family.Ask how the target tracks device identifiers across releases.
Class II use (para. (f))In the case of a Class II medical device other than a decorative contact lens, a change in the medical conditions, purposes or uses for which the device is manufactured, sold or represented.Ask whether the target has widened the claims it makes for the software.
General information, not legal advice.

Ask for a release history showing each change to the model, the training data and the software since the licence was issued, and how the target classified them.

Good machine learning practice as the diligence lens

The FDA, Health Canada and the MHRA have jointly identified 10 guiding principles that can inform the development of Good Machine Learning Practice (GMLP). The list includes multi-disciplinary expertise leveraged throughout the total product life cycle and good software engineering and security practices. It also includes clinical study participants and data sets that are representative of the intended patient population, and training data sets that are independent of test sets.

The principles also say that where the model has a “human in the loop,” human factors considerations and the human interpretability of the model outputs are addressed with emphasis on the performance of the Human-AI team, rather than just the performance of the model in isolation. Under the principles, deployed models have the capability to be monitored in “real world” use with a focus on maintained or improved safety and performance. The same principle says that when models are periodically or continually trained after deployment, there are appropriate controls in place to manage risks of overfitting, unintended bias or degradation of the model (for example, dataset drift) that may impact the safety and performance of the model as it is used by the Human-AI team.

Ask the target to show how its practice matches the principles, and who at the company can explain any gap. For the data, model and IP side of an AI sale, see data, model and IP transfers in an AI business sale.

Checking the target’s licences and establishment licence

The Medical Devices Active Licence Listing (MDALL) page says the Bureau maintains a database of all licensed Class II, III and IV medical devices offered for sale in Canada. Class I devices, and devices which relate to Investigational Testing Authorization or Special Access, do not appear in that listing. A search can be done by company name, company ID, licence name, licence number, device name or device identifier. Class I medical devices do not require a medical device licence and are monitored by the Health Products and Food Branch Inspectorate (Compliance and Enforcement) through establishment licensing. Ask the seller for each licence number, check it against the listing yourself, and compare the device name and identifier with what the target actually sells. For a plain definition, see the medical device licence glossary entry.

Under section 44(1) of the Regulations, no person may import or sell a medical device unless the person holds an establishment licence. Section 44(2) lists exemptions, among them retailers, health care facilities and, in the case of a Class II, III or IV medical device, the manufacturer of the device, and, in the case of a Class I device, a manufacturer that imports or distributes solely through a person who holds an establishment licence. Under section 44(3), a person who imports a medical device must ensure that the person from whom they import it holds an establishment licence, except when importing a Class I device from its manufacturer while holding an establishment licence, or a Class II, III or IV device from its manufacturer.

Under section 46.1, the holder of an establishment licence that is not suspended must submit an application for the review of the licence to the Minister before April 1 of each year, with the information and documents referred to in section 45. If, after issue, there is a change to any of the information referred to in paragraph 45(a) or (b), the holder must submit the new information to the Minister within 15 days of the change. Health Canada’s establishment licence page links to the Medical Devices Establishment Licence Live Listing. Ask whether the target holds an establishment licence, which activity it states, and whether the annual review was filed; the glossary has the establishment licence entry.

Quality management system certificates

Section 32(2) of the Regulations says an application for a Class II medical device licence contains, in addition to the information and documents in subsection (1), among other items, a copy of the quality management system certificate certifying that the quality management system under which the device is manufactured meets the requirements of the National Standard of Canada CAN/CSA-ISO 13485, Medical devices — Quality management systems — Requirements for regulatory purposes, as amended from time to time. Section 32(3) says an application for a Class III medical device licence contains, in addition to subsection (1), among other items, a copy of a quality management system certificate certifying that the quality management system under which the device is designed and manufactured meets the requirements of the same standard.

This guide does not set out the Class IV list, so ask a regulatory lawyer what a Class IV application contains. Ask the target for its current certificate, the body that issued it and the date of issue. The AI business buyer checklist covers the wider purchase.

Questions to ask before you buy

  • What does the target’s labelling, website and promotional material say the software is for?
  • Which class has the target declared, and has Health Canada confirmed it?
  • Which licence numbers does the target hold, and do they match the listing?
  • Has any release since licensing changed the design, software or intended use?
  • Does the target retrain its model, and is that retraining described in an authorized change control plan?
  • Does the target hold an establishment licence, and was the annual review filed?
  • Can the target show its quality management system certificate?
  • What does a change of owner, or a renaming after closing, do to each licence?

Questions people ask

Short answers; each links to the full page.

How do I check whether a medical device is licensed in Canada?
Health Canada keeps a database of all licensed Class II, III and IV medical devices offered for sale in Canada. It can be searched by company name or ID, licence name or number, and device name or identifier. Class I devices do not appear in it. Full answer
Who needs a medical device establishment licence in Canada?
Under the federal Medical Devices Regulations, no person imports or sells a medical device unless the person holds an establishment licence, subject to the exceptions in section 44(2), including retailers and health care facilities. Health Canada’s guidance says importers and distributors need an active MDEL for all classes of device, subject to the listed exemptions. Full answer
How do I renew a medical device establishment licence?
Health Canada says an MDEL does not expire annually and continues to be valid as long as the holder submits its annual licence review application before April 1 each year and pays the associated fee. If the application is not submitted before April 1, it says it will cancel the MDEL starting on April 1. Full answer

Related reading

13 pages on the same subject, grouped by topic.

Sources

Every requirement and figure referenced in this guide traces to a primary source. Links were last confirmed on the dates shown.

  1. 01
  2. 02
    Government of Canada (Department of Justice)Government
    Medical Devices Regulations, SOR/98-282
    laws-lois.justice.gc.ca·Checked Oct 21, 2026
  3. 03
    Health CanadaRegulator
    Pre-market guidance for machine learning-enabled medical devices
    canada.ca·Checked Nov 19, 2026
  4. 04
  5. 05
  6. 06
    Health CanadaRegulator
    Medical Devices Active Licence Listing (MDALL)
    canada.ca·Checked Nov 19, 2026
  7. 07
    Health CanadaGovernment
    Medical Device Establishment Licences
    canada.ca·Checked Aug 16, 2026

Deavo is an advertising and listings platform, not a brokerage, law firm or valuation firm. This page is general information, not legal, tax, accounting or valuation advice, and rules differ by province. Confirm anything you rely on with a qualified professional before you act on it.